Horn has installed its first online gas analysis unit on furnace 62 at Vetropack's Straza, Croatia, site.

The flue gas analyser, from ABB Automation, was installed to measure CO, CO2, NO and O2. The exhaust gas measurement consists of a gas sampling, sample conditioning and an analysis unit.

The measurements are carried out at three different locations: at each regenerator crown and one measurement in the exhaust channel after the reversal unit.

During operation the measurement is switched every 20 minutes at the reversal process between the sensors in the regenerator crown. At the third probe once a day is measured.

The measured exhaust gas components are displayed on the control system and can be observed continuously so the optimal combustion can be monitored.

A control of the combustion using the measured values is provided.